ANALYSIS OF AN ELECTRODIALYSIS UNIT ON THE BASIS OF IRREVERSIBLE THERMODYNAMICS

Authors
Citation
S. Koter, ANALYSIS OF AN ELECTRODIALYSIS UNIT ON THE BASIS OF IRREVERSIBLE THERMODYNAMICS, Desalination, 95(2), 1994, pp. 139-153
Citations number
18
Categorie Soggetti
Water Resources","Engineering, Chemical
Journal title
ISSN journal
00119164
Volume
95
Issue
2
Year of publication
1994
Pages
139 - 153
Database
ISI
SICI code
0011-9164(1994)95:2<139:AOAEUO>2.0.ZU;2-6
Abstract
The performance of an ED basic unit is analyzed on the basis of irreve rsible thermodynamics. The influence of the thickness of polarization layers, the distance between membranes, the concentration of diluate, and the current density as well as the transport coefficients of membr anes on the current efficiency, CE, and the efficiency of energy conve rsion, eta, is shown.