EVALUATION OF A HIGH-PERFORMANCE MAGNETICALLY SHIELDED ROOM FOR BIOMAGNETIC MEASUREMENT

Citation
K. Harakawa et al., EVALUATION OF A HIGH-PERFORMANCE MAGNETICALLY SHIELDED ROOM FOR BIOMAGNETIC MEASUREMENT, IEEE transactions on magnetics, 32(6), 1996, pp. 5256-5260
Citations number
12
Categorie Soggetti
Engineering, Eletrical & Electronic","Physics, Applied
ISSN journal
00189464
Volume
32
Issue
6
Year of publication
1996
Pages
5256 - 5260
Database
ISI
SICI code
0018-9464(1996)32:6<5256:EOAHMS>2.0.ZU;2-K
Abstract
A spherical magnetically shielded room called COSMOS and a method for measuring the shielding factor of well-shielded rooms have been develo ped. A dc-superconducting quantum interference device is used to detec t faint magnetic fields, and the detected signals are averaged to incr ease-the signal-to-noise ratio. The measured magnetic shielding factor for COSMOS is 420 000 at 1 Hz.