ABSORPTION RESORPTION HEATING CYCLES WITH THE NEW WORKING PAIRS R21-NMP AND R21-DMA

Citation
Ms. Bhatt et al., ABSORPTION RESORPTION HEATING CYCLES WITH THE NEW WORKING PAIRS R21-NMP AND R21-DMA, Energy conversion and management, 35(5), 1994, pp. 443-451
Citations number
NO
Categorie Soggetti
Energy & Fuels",Mechanics,"Physics, Nuclear",Thermodynamics
ISSN journal
01968904
Volume
35
Issue
5
Year of publication
1994
Pages
443 - 451
Database
ISI
SICI code
0196-8904(1994)35:5<443:ARHCWT>2.0.ZU;2-I
Abstract
The new working pairs, R21-NMP and R21-DMA, find potential application as working pairs for the single stage Resorption Heat Pump (RHP) and the Resorption Heat Transformer (RHT) cycles. A thermodynamic cycle an alysis with these pairs shows that single stage RHPs have high COPs in their entire range of operation. RHTs show higher temperature boosts (up to 47 K) than the simple absorption heat transformers. Absorber te mperatures of up to 400 K can be achieved in a single stage RHT system using R21 as the refrigerant. However, absorption-resorption systems have inherent limitations on the range of operating temperatures. Besi des, they necessitate a higher pump work as compared to simple single stage absorption heating systems.