EDDY-CURRENT LOSSES AND NUMBER OF DOMAIN-WALLS WITH RESPECT TO TOTAL NUMBER OF LAYERS FOR VERY THIN 3-PERCENT SI-FE STRIP-WOUND CORES
Citation
Ki. Arai et al., EDDY-CURRENT LOSSES AND NUMBER OF DOMAIN-WALLS WITH RESPECT TO TOTAL NUMBER OF LAYERS FOR VERY THIN 3-PERCENT SI-FE STRIP-WOUND CORES, Journal of magnetism and magnetic materials, 133(1-3), 1994, pp. 198-200
Categorie Soggetti
Material Science","Physics, Condensed Matter
SICI code
0304-8853(1994)133:1-3<198:ELANOD>2.0.ZU;2-Z
Abstract
The relation between the domain wall motion and the eddy current losse
s of very thin (110)[001] 3% Si-Fe strip-wound cores were investigated
. The measured eddy current losses were larger than those estimated us
ing a modified Pry and Bean model in the frequency region 50-500 Hz. I
t is known that the domain walls of thick (110)[001] 3% Si-Fe strips m
ove nonuniformly in the low-frequency range (0.1-100 Hz), but this fre
quency range is lower than that usually used for very thin strips. By
measuring the flux voltage in every layer, we found that the voltage w
aveforms were not sinusoidal, even if the secondary voltage waveform o
f the core was sinusoidal, and the magnitude of the voltage in each la
yer was not uniform. These results indicate that the domain wall motio
n of very thin strips is not uniform, even at 50-500 Hz. The nonunifor
mity of the domain wall motion makes the eddy current losses larger th
an those estimated by means of the modified Pry and Bean model.