L. Hesse et al., COMPUTER-ASSISTED, IMPROVED ANALYSIS OF C OMBERG RADIOGRAMS BY MEANS OF A 3-DIMENSIONAL VISUALIZATION, Klinische Monatsblatter fur Augenheilkunde, 204(4), 1994, pp. 248-251
Background Small metallic foreign bodies may easily be identified by c
onventional x-ray. The Comberg shell is a useful tool to discriminate
between extra-respectively intraocular localization of the foreign bod
y. However, poor results are common when evaluating the x-ray films. M
ethods We have improved evaluation of the radiographs by means of a pr
ogram for a personal computer, regarding the following aspects: To avo
id errors of measurement the relevant points of the radiograms are rea
d by a digitizer-tableau. The different projection failure of the late
ral respectively posteroanterior x-ray is calculated separatly. For th
e calculation of the modell the true axial length of the eye is consid
ered. Conclusion A three dimensional image from varying points of view
gives an instructive impression of the foreign body and its relation
to structures of the eye. Handling of the presented computer program i
s easy. It standardizes analysis of the Comberg radiograms.