ASSESSMENT OF REDUCIBILITY OF ILEOCOLIC INTUSSUSCEPTION IN CHILDREN -USEFULNESS OF COLOR DOPPLER SONOGRAPHY

Citation
Hk. Lim et al., ASSESSMENT OF REDUCIBILITY OF ILEOCOLIC INTUSSUSCEPTION IN CHILDREN -USEFULNESS OF COLOR DOPPLER SONOGRAPHY, Radiology, 191(3), 1994, pp. 781-785
Citations number
24
Categorie Soggetti
Radiology,Nuclear Medicine & Medical Imaging
Journal title
ISSN journal
00338419
Volume
191
Issue
3
Year of publication
1994
Pages
781 - 785
Database
ISI
SICI code
0033-8419(1994)191:3<781:AOROII>2.0.ZU;2-H
Abstract
PURPOSE: To assess the diagnostic usefulness of ultrasonography (US) i n intussusception in children and determine whether color Doppler sono graphy (CDS) can indicate bowel viability and help in prediction of re ducibility. MATERIALS AND METHODS: US was used to examine 176 children in whom the presence of intussusception was clinically suspected. CDS was performed in 64 patients with 65 cases of intussusception proved with US. RESULTS: The positive US findings were confirmed with air ene ma; the negative findings, with air enema in 46 patients and clinical follow-up in 66 patients (100% specificity and sensitivity). CDS indic ated blood flow in 62 of 65 cases of intussusception; pneumatic reduct ion was achieved in 58 (94%) of these 62 cases. Four patients (6%) und erwent manual reduction of viable bowel; three patients (5%) who had n o color Doppler signal underwent segmental resection. The difference i n reduction rates based on blood flow was statistically significant (P = .0008). CONCLUSION: US is sensitive and specific in the diagnosis o f intussusception, and CDS is a promising predictor of bowel viability .