PERMEABILITY AND MICROSTRUCTURE OF PLAIN AND POLYPROPYLENE FIBER-REINFORCED GROUTS

Citation
Ml. Allan et Le. Kukacka, PERMEABILITY AND MICROSTRUCTURE OF PLAIN AND POLYPROPYLENE FIBER-REINFORCED GROUTS, Cement and concrete research, 24(4), 1994, pp. 671-681
Citations number
15
Categorie Soggetti
Construcion & Building Technology","Material Science
ISSN journal
00088846
Volume
24
Issue
4
Year of publication
1994
Pages
671 - 681
Database
ISI
SICI code
0008-8846(1994)24:4<671:PAMOPA>2.0.ZU;2-T
Abstract
Cementitious grouts with and without polypropylene fibres were evaluat ed for use as containment barriers around waste landfills located in a n arid environment. Viscosity, flow time, water permeability and micro structure of the grouts were investigated. Low permeabilities of the o rder of 10(-11) to 10(-10) cm/s were measured on cement-sand grouts. P ermeability was influenced by curing conditions and water/cement ratio . Variation of sand/cement ratio by mass from 1 to 1.2 and addition of 0.1 to 0.2% volume fraction fibres did not affect permeability signif icantly.