THE COTREL-DUBOUSSET INSTRUMENTATION FOR UNSTABLE SACRAL FRACTURES - REPORT OF 3 PATIENTS

Citation
Hh. Strangevognesen et al., THE COTREL-DUBOUSSET INSTRUMENTATION FOR UNSTABLE SACRAL FRACTURES - REPORT OF 3 PATIENTS, Acta orthopaedica Scandinavica, 65(2), 1994, pp. 219-220
Citations number
3
Categorie Soggetti
Orthopedics
ISSN journal
00016470
Volume
65
Issue
2
Year of publication
1994
Pages
219 - 220
Database
ISI
SICI code
0001-6470(1994)65:2<219:TCIFUS>2.0.ZU;2-M
Abstract
We present a new operative procedure using the Cotrel-Dubousset (C-D) instrumentation in unstable sacral fractures, where the vertebral colu mn is dissociated from the pelvis. This technique is based on screw fi xation in the ileum and in the first sacral and the fifth lumbar verte brae or the fifth and fourth lumbar vertebrae, with help of interconne cting rods. 3 patients were successfully treated.