Nm. Zoumakis et al., DETERMINATION OF VERTICAL DISPERSION PARAMETERS IN THE INDUSTRIAL-AREA OF THESSALONIKI, GREECE USING SPECTROPHOTOMETRIC MEASUREMENTS, Fresenius environmental bulletin, 3(3), 1994, pp. 164-168
Data from a Brewer spectrophotometer are used to calculate the vertica
l dispersion parameters of Gaussian and non-Gaussian plumes from eleva
ted point sources in the industrial area of Thessaloniki. Using Gaussi
an, non-Gaussian and numerical grid (box) air pollution models, the es
timation of vertical spread and plume rise from tall stacks can be obt
ained from combined columnar and ground-level concentrations.