DETERMINATION OF VERTICAL DISPERSION PARAMETERS IN THE INDUSTRIAL-AREA OF THESSALONIKI, GREECE USING SPECTROPHOTOMETRIC MEASUREMENTS

Citation
Nm. Zoumakis et al., DETERMINATION OF VERTICAL DISPERSION PARAMETERS IN THE INDUSTRIAL-AREA OF THESSALONIKI, GREECE USING SPECTROPHOTOMETRIC MEASUREMENTS, Fresenius environmental bulletin, 3(3), 1994, pp. 164-168
Citations number
NO
Categorie Soggetti
Environmental Sciences
ISSN journal
10184619
Volume
3
Issue
3
Year of publication
1994
Pages
164 - 168
Database
ISI
SICI code
1018-4619(1994)3:3<164:DOVDPI>2.0.ZU;2-U
Abstract
Data from a Brewer spectrophotometer are used to calculate the vertica l dispersion parameters of Gaussian and non-Gaussian plumes from eleva ted point sources in the industrial area of Thessaloniki. Using Gaussi an, non-Gaussian and numerical grid (box) air pollution models, the es timation of vertical spread and plume rise from tall stacks can be obt ained from combined columnar and ground-level concentrations.