MEASUREMENT OF PARTICLE EMISSIONS FROM CLEAN ROOM GAS-HANDLING COMPONENTS

Citation
R. Periasamy et al., MEASUREMENT OF PARTICLE EMISSIONS FROM CLEAN ROOM GAS-HANDLING COMPONENTS, Journal of the Electrochemical Society, 141(6), 1994, pp. 1649-1653
Citations number
3
Categorie Soggetti
Electrochemistry
ISSN journal
00134651
Volume
141
Issue
6
Year of publication
1994
Pages
1649 - 1653
Database
ISI
SICI code
0013-4651(1994)141:6<1649:MOPEFC>2.0.ZU;2-V
Abstract
Particle emissions from clean room gas-handling components were measur ed by following a test method developed recently by SEMATECH. Three ty pes of tests, namely, the static, the dynamic, and the impact tests we re conducted to determine particle emissions from the components teste d. Particles emitted by the components such as valves, point-of-use fi lters and inline pressure regulators were measured using a condensatio n nucleus particle counter. The number of particles emitted by the val ve was influenced by the actuator pressure used to open and close the test valve. That is, the higher the actuator pressure the higher the n umber of particles released from the automatic valve. Particle contrib utions measured from valves, filters, and regulators are presented her e.