SMALL-GAP WIDTH MEASUREMENT WITH A FINITE X-RAY SOURCE

Authors
Citation
B. Karp et G. Adam, SMALL-GAP WIDTH MEASUREMENT WITH A FINITE X-RAY SOURCE, NDT & E international, 27(1), 1994, pp. 21-25
Citations number
11
Categorie Soggetti
Materials Science, Characterization & Testing
Journal title
ISSN journal
09638695
Volume
27
Issue
1
Year of publication
1994
Pages
21 - 25
Database
ISI
SICI code
0963-8695(1994)27:1<21:SWMWAF>2.0.ZU;2-H
Abstract
Theoretical work was carried out in order to assess the feasibility of measuring small gap widths by using X-rays. The work was done using o ptical geometry, and the effect of the various geometrical parameters (source dimension, geometrical enlargement, gap width, and film positi on relative to the no-umbra point) on the apparent gap size was invest igated. The influence of some other parameters (eg full reflectance of the beam from the gap edges or misalignment of the source and the gap axis) is also discussed. The results, which are presented graphically and analytically, enable the user to plan a measurement in an optimal way and help in analysing the results correctly.