I. Petrov et E. Schlegel, APPLICATION OF AUTOMATIC IMAGE-ANALYSIS FOR THE INVESTIGATION OF AUTOCLAVED AERATED CONCRETE STRUCTURE, Cement and concrete research, 24(5), 1994, pp. 830-840
Citations number
12
Categorie Soggetti
Construcion & Building Technology","Material Science
Automatic image analysis in connection with stereology and stochastic
geometry was used to describe the size distribution of air pores in au
toclaved concrete. The experiments were carried out on AAC samples wit
h extremely different bulk densities and compressive strengths. The as
sumption of an elliptic shape of pores leads to an unambiguous charact
erisation of structure by bi-histograms. It will be possible to calcul
ate the spatial pore size distribution by these histograms, if the por
es are assumed as being spheroids. A marked point field model and the
pair correlation function g(a)(r) were used to describe the pore struc
ture.