IMPROVED LONGITUDINAL MAGNETIC SHIELDING BY AN AMORPHOUS FE-SI STEEL COMPOSITE PANEL

Authors
Citation
Y. Okazaki et H. Mogi, IMPROVED LONGITUDINAL MAGNETIC SHIELDING BY AN AMORPHOUS FE-SI STEEL COMPOSITE PANEL, Materials science & engineering. A, Structural materials: properties, microstructure and processing, 182, 1994, pp. 1374-1377
Citations number
5
Categorie Soggetti
Material Science
ISSN journal
09215093
Volume
182
Year of publication
1994
Pages
1374 - 1377
Database
ISI
SICI code
0921-5093(1994)182:<1374:ILMSBA>2.0.ZU;2-U
Abstract
An improved magnetic shielding using the magnetic shaking technique wi th a planar mesh coil is applied to develop a composite shielding pane l of Fe-based amorphous sheet and Si steel sheet. The mesh coil, sandw iched by the two ferromagnetic materials, makes a two-dimensional shak ing field that enhances magnetic shielding. The composite panel anneal ed without field shows exceedingly high longitudinal shielding effecti veness. Fine and circular magnetic domains of amorphous Fe-based ribbo ns contribute to the magnetic shielding effectiveness for alternating fields at high frequencies.