EVALUATION OF ASEISMIC INTEGRITY IN HTTR CORE-BOTTOM STRUCTURE .3. STRUCTURAL INTEGRITY OF CORE SUPPORT POST COMPONENT

Citation
M. Ishihara et al., EVALUATION OF ASEISMIC INTEGRITY IN HTTR CORE-BOTTOM STRUCTURE .3. STRUCTURAL INTEGRITY OF CORE SUPPORT POST COMPONENT, Nuclear Engineering and Design, 148(1), 1994, pp. 91-100
Citations number
11
Categorie Soggetti
Nuclear Sciences & Tecnology
ISSN journal
00295493
Volume
148
Issue
1
Year of publication
1994
Pages
91 - 100
Database
ISI
SICI code
0029-5493(1994)148:1<91:EOAIIH>2.0.ZU;2-N
Abstract
Component testing of the core support post for the high temperature en gineering test reactor (HTTR) was carried out to verify its structural integrity using full-scale and 1/2-scale models. The compressive frac ture load was measured at room temperature under the conditions of pos t inclination up to about 1 degree, cyclic load up to 200 times and ox idation up to about 30% of oxidation weight-loss. In this paper, the e ffects of post inclination angle, cyclic load and oxidation weight-los s of this component on the compressive fracture load were discussed an d the fracture load was compared with the design load of the HTTR.