M. Ishihara et al., EVALUATION OF ASEISMIC INTEGRITY IN HTTR CORE-BOTTOM STRUCTURE .3. STRUCTURAL INTEGRITY OF CORE SUPPORT POST COMPONENT, Nuclear Engineering and Design, 148(1), 1994, pp. 91-100
Component testing of the core support post for the high temperature en
gineering test reactor (HTTR) was carried out to verify its structural
integrity using full-scale and 1/2-scale models. The compressive frac
ture load was measured at room temperature under the conditions of pos
t inclination up to about 1 degree, cyclic load up to 200 times and ox
idation up to about 30% of oxidation weight-loss. In this paper, the e
ffects of post inclination angle, cyclic load and oxidation weight-los
s of this component on the compressive fracture load were discussed an
d the fracture load was compared with the design load of the HTTR.