D. Raftery et al., MULTIPLE-PULSE NUCLEAR-MAGNETIC-RESONANCE OF OPTICALLY PUMPED XENON IN A LOW MAGNETIC-FIELD, Physical review. A, 50(1), 1994, pp. 567-574
Multiple-pulse coherent averaging methods are used to increase the res
olution and frequency range of optically pumped xenon NMR in nutation
and point-by-point precession experiments. We observe quadrupolar spli
ttings in Xe-131 spectra due to the macroscopic asymmetry of pumping c
ells similar to those reported previously, but with reduced demands on
magnetic-field homogeneity. Cell treatment with hydrogen gas increase
s the quadrupolar splittings by a factor of 3 over bare Pyrex cells.