HARDWARE LINEARIZATION OF THERMISTOR RESPONSE USING SERIES-PARALLEL RESISTORS FOR TEMPERATURE-TO-TIME CONVERSION

Citation
S. Kaliyugavaradan et al., HARDWARE LINEARIZATION OF THERMISTOR RESPONSE USING SERIES-PARALLEL RESISTORS FOR TEMPERATURE-TO-TIME CONVERSION, Measurement science & technology, 5(7), 1994, pp. 786-788
Citations number
6
Categorie Soggetti
Instument & Instrumentation",Engineering
ISSN journal
09570233
Volume
5
Issue
7
Year of publication
1994
Pages
786 - 788
Database
ISI
SICI code
0957-0233(1994)5:7<786:HLOTRU>2.0.ZU;2-P
Abstract
A scheme is suggested for obtaining linear temperature-to-time period conversion using series-parallel resistors with a thermistor. The circ uitry presented for realizing the proposed converters possesses the ad vantage of easily adjustable sensitivity. An experimental temperature- to-time converter constructed for a standard thermistor provides an ac curacy better than 0.1 K over the range 35-95-degrees-C.