APPLICATION OF A PORTABLE CLAMP-ON ULTRASONIC FLOWMETER IN THE WATER INDUSTRY

Authors
Citation
F. Cascetta, APPLICATION OF A PORTABLE CLAMP-ON ULTRASONIC FLOWMETER IN THE WATER INDUSTRY, FLOW MEASUREMENT AND INSTRUMENTATION, 5(3), 1994, pp. 191-194
Citations number
NO
Categorie Soggetti
Instument & Instrumentation","Engineering, Mechanical
ISSN journal
09555986
Volume
5
Issue
3
Year of publication
1994
Pages
191 - 194
Database
ISI
SICI code
0955-5986(1994)5:3<191:AOAPCU>2.0.ZU;2-1
Abstract
This paper illustrates the experimental results obtained in a volume f low rate measurement application performed in the water industry. A cl amp-on (transit time) portable ultrasonic flowmeter is compared to an in-line (or wetted) electromagnetic meter (used as a master meter). Bo th meters are mounted in series along a long stretch of pipe in a wate r distribution network. This in situ comparison gives satisfactory res ults, since the measurements provided by the two flowmeters are substa ntially in accordance.