MEASUREMENT OF THE RESISTANCE TO STRESS CYCLING AT 4.2 K OF LHC DIPOLE COLLARS

Citation
D. Perini et al., MEASUREMENT OF THE RESISTANCE TO STRESS CYCLING AT 4.2 K OF LHC DIPOLE COLLARS, IEEE transactions on magnetics, 30(4), 1994, pp. 1754-1757
Citations number
4
Categorie Soggetti
Engineering, Eletrical & Electronic","Physics, Applied
ISSN journal
00189464
Volume
30
Issue
4
Year of publication
1994
Part
2
Pages
1754 - 1757
Database
ISI
SICI code
0018-9464(1994)30:4<1754:MOTRTS>2.0.ZU;2-G
Abstract
At each operation cycle of the LHC machine, the field of the supercond ucting dipoles will be raised from the injection level to the collisio n level and then decreased again. This will induce a stress cycle insi de the structure. The collars will have to withstand several thousands of stress cycles during their life. In this paper a description of th e test apparatus built to assess the strength of different types of co llars is given. We also present results of measurements and draw some preliminary conclusions regarding the influence of material properties , geometry and surface condition, on the endurance of the collars.