GATED X-RAY IMAGER GAIN CORRECTION USING A TAPERED MICROCHANNEL-PLATESTRIPLINE

Citation
Rg. Watt et al., GATED X-RAY IMAGER GAIN CORRECTION USING A TAPERED MICROCHANNEL-PLATESTRIPLINE, Review of scientific instruments, 65(8), 1994, pp. 2585-2586
Citations number
5
Categorie Soggetti
Physics, Applied","Instument & Instrumentation
ISSN journal
00346748
Volume
65
Issue
8
Year of publication
1994
Pages
2585 - 2586
Database
ISI
SICI code
0034-6748(1994)65:8<2585:GXIGCU>2.0.ZU;2-S
Abstract
Gated imagers used to record x-ray emission in the 1-5 keV range in la ser-plasma interaction experiments have suffered from resistive gain d egradation between voltage drive pulse input and output ends of a micr ochannel-plate stripline. The reduction in gain as the pulse travels d own the strip results in a lower signal-to-background ratio in the las t image on a strip than in the first image. Compensation for this gain nonuniformity using a tapered stripline in place of the normally stra ight striplines is discussed.