Ar. Samo et al., THE SIMULTANEOUS ANALYSIS OF THEOPHYLLINE, CAFFEINE AND THEIR METABOLITES IN HUMAN PLASMA BY HPLC, Journal of the Chemical Society of Pakistan, 15(3), 1993, pp. 182-186
Theoplline, caffeine and their important metabolites were extracted fr
om human plasma using newly developed solid support liquid/liquid extr
action tubes. These substances were separated on a 3 mum ODS (250 x 4.
6 mm i.d) column with a mobile phase gradient and detected with a UV d
iode array detector set at two wave lengths of 270 and 290 nm. The nor
mal ranges for the plasma drug/metabolite molar ratios have been deter
mined.