Pp. Allport et al., THE OPAL SILICON STRIP MICROVERTEX DETECTOR WITH 2 COORDINATE READOUT, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 346(3), 1994, pp. 476-495
The OPAL experiment at the CERN LEP collider recently upgraded its sil
icon strip microvertex detector from one coordinate readout (phi only)
to two coordinate readout (phi and z). This allows three dimensional
vertex reconstruction and should improve lifetime measurements as well
as b quark jet identification. This paper describes the new microvert
ex detector system with emphasis on the novel techniques and new compo
nents used to obtain the second coordinate information. These include
the use of back-to-back single-sided detectors with orthogonally orien
ted readout strips, a gold printed circuit on a thin glass substrate t
o route the z strip signals to the electronics at the end of the detec
tor, and the use of MX7 readout chips. Results on the performance of t
he new detector are presented.