EXPERIMENTAL-ANALYSIS OF THE MULTI-BYPASS PRINCIPLE IN PULSE TUBE REFRIGERATORS

Citation
Jh. Cai et al., EXPERIMENTAL-ANALYSIS OF THE MULTI-BYPASS PRINCIPLE IN PULSE TUBE REFRIGERATORS, Cryogenics, 34(9), 1994, pp. 713-715
Citations number
3
Categorie Soggetti
Physics, Applied",Thermodynamics
Journal title
ISSN journal
00112275
Volume
34
Issue
9
Year of publication
1994
Pages
713 - 715
Database
ISI
SICI code
0011-2275(1994)34:9<713:EOTMPI>2.0.ZU;2-G
Abstract
This paper describes the structural characteristics and the mechanical performance of a co-axial pulse tube refrigerator with a multi-bypass . Some experimental results and an experimental analysis of the multi- bypass method are also given. The minimum attainable temperature at th e cold end of a co-axial pulse tube refrigerator with multi-bypass is 33 K at a vacuum of 1 x 10(-4) torr. This shows that the performance o f a pulse lube refrigerator is comparable to that of a Stirling refrig erator. Moreover, pulse tube systems would probably be more extensivel y used than Stirling refrigerators because of their advantages in term s of structural simplicity and mechanical reliability.