RESULTS FROM THE SLD BARREL CRID DETECTOR

Citation
K. Abe et al., RESULTS FROM THE SLD BARREL CRID DETECTOR, IEEE transactions on nuclear science, 41(4), 1994, pp. 862-865
Citations number
10
Categorie Soggetti
Nuclear Sciences & Tecnology","Engineering, Eletrical & Electronic
ISSN journal
00189499
Volume
41
Issue
4
Year of publication
1994
Part
1
Pages
862 - 865
Database
ISI
SICI code
0018-9499(1994)41:4<862:RFTSBC>2.0.ZU;2-H
Abstract
We report on operational experience with an experimental performance o f the SLD barrel Cherenkov Ring Imaging Detector from the 1992 and 199 3 physics runs. The liquid (C6F14) and gas (C5F12) radiator recirculat ion systems have performed well, and the drift gas supply system has o perated successfully with TMAE for three years. Cherenkov rings have b een observed from both the liquid and gas radiators. The number and an gular resolution of Cherenkov photons have been measured, and found to be close to design specifications.