Mixing time, circulation time and downcomer linear liquid velocity wer
e measured in two sizes of external-loop airlift bioreactors with Newt
onian and non-Newtonian fluids. The mixing time increased as a result
of an increase of non-Newtonian characteristics. However, the liquid c
irculation time was affected only slightly by non-Newtonian flow behav
ior. A semi-empirical correlation for circulation time in external-loo
p airlift bioreactors was proposed. The proposed correlation was compa
red with the present experimental results and those in the literature.
Reasonable agreement was obtained between the predicted and experimen
tal values of circulation times. The downcomer liquid velocity was alm
ost independent of the downcomer-to-riser cross-sectional area ratio.
The correlation based on the concept of an eddy diffusivity predicted
downcomer liquid velocities in Newtonian and non-Newtonian fluids.