VAPOR-SIDE CORROSION OF COPPER-BASE CONDENSER TUBES OF THE MSF DESALINATION PLANTS OF ABU-DHABI

Citation
Ea. Alsum et al., VAPOR-SIDE CORROSION OF COPPER-BASE CONDENSER TUBES OF THE MSF DESALINATION PLANTS OF ABU-DHABI, Desalination, 97(1-3), 1994, pp. 109-119
Citations number
21
Categorie Soggetti
Water Resources","Engineering, Chemical
Journal title
ISSN journal
00119164
Volume
97
Issue
1-3
Year of publication
1994
Pages
109 - 119
Database
ISI
SICI code
0011-9164(1994)97:1-3<109:VCOCCT>2.0.ZU;2-O
Abstract
During the past 25 years of operation of Abu Dhabi desalination plants considerable information has been gathered on the vapour side corrosi on of copper base condenser tubes. The present paper describes the phe nomenon, its causes, characteristics and mode of action of two types o f corrosion. The paper also outlines Abu Dhabi Water and Electricity D epartment (WED) experience in the field.