THE ARGUS SILICON VERTEX DETECTOR

Citation
E. Michel et al., THE ARGUS SILICON VERTEX DETECTOR, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 348(2-3), 1994, pp. 465-469
Citations number
12
Categorie Soggetti
Nuclear Sciences & Tecnology","Physics, Particles & Fields","Instument & Instrumentation",Spectroscopy
ISSN journal
01689002
Volume
348
Issue
2-3
Year of publication
1994
Pages
465 - 469
Database
ISI
SICI code
0168-9002(1994)348:2-3<465:TASVD>2.0.ZU;2-K
Abstract
A silicon microstrip vertex detector has been built as an upgrade to t he ARGUS detector for increased precision and efficiency in the recons truction of decay vertices. This paper discusses the mechanical and el ectronic design of this device and presents first results from its suc cessful test operation yielding an impact parameter resolution of abou t 18 mum.