So. Nelson et Kc. Lawrence, RF IMPEDANCE AND DC CONDUCTANCE DETERMINATION OF MOISTURE IN INDIVIDUAL SOYBEANS, Transactions of the ASAE, 37(1), 1994, pp. 179-182
Two electrical methods for determining the moisture content of single
soybeans were compared to an oven drying reference method for moisture
measurement. Moisture contents of the soybeans ranged from 7 to 20%,
wet basis. A commercial instrument that measured the dc conductance of
the soybeans as they passed between crushing-roller electrodes gave m
oisture contents with a standard error of 0.68% moisture over measurem
ents on soybeans of four cultivars from soybean producing areas in the
Midwest and the Southeast. Capacitance measurements at 1 and 5 MHz on
the same single soybeans, held between and in contact with 2-cm-diame
ter parallel-plate electrodes, produced moisture content determination
s with a standard error of 0.56% moisture content. Thus, both techniqu
es offer comparable accuracies when suitably calibrated.