A time-resolved shearographic detection method is described which empl
oys controlled thermal loading to produce both thermal and thermoelast
ic responses and allows defect depth to be determined. A comparison is
made between this shearographic approach and conventional thermograph
ic methods for nondestructive evaluation. Results are presented for a
graphite-epoxy/honeycomb composite specimen with delaminations between
the skin and the honeycomb core.