X. Cai et al., SIMULTANEOUS DETERMINATION OF URIC-ACID, XANTHINE AND HYPOXANTHINE WITH AN ELECTROCHEMICALLY PRETREATED CARBON-PASTE ELECTRODE, Fresenius' journal of analytical chemistry, 348(10), 1994, pp. 660-665
A simple method is presented for the simultaneous differential pulse v
oltammetric determination of uric acid, xanthine and hypoxanthine. It
is based on the improved current responses of the three analytes at ca
rbon paste electrodes polarized in a dilute alkaline medium (0.002 mol
/l NaOH, 0.1 mol/l NaClO4) at 1.3 V vs. SCE for a short time. Compared
with the methods reported in the literature, this procedure has a muc
h wider linear range (2 to 3 orders of magnitude in concentration), lo
wer detection limits (5 to 10 mug 1(-1) and less interference by ascor
bic acid. The electrochemical responses were found to be dependent on
the pre-anodization potential and the time imposed on the electrodes a
s well as on the alkalinity of the supporting electrolyte. The propose
d procedure was used to determine uric acid, xanthine and hypoxanthine
in human urine without any preliminary treatment.