U. Muller et al., A RICH DETECTOR WITH 2-STAGE GAS AMPLIFICATION AT ATMOSPHERIC-PRESSURE, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 343(1), 1994, pp. 203-207
A prototype of a Ring Imaging Cherenkov detector (RICH) with two-stage
gas amplification has been developed. The detector consists of a time
projection chamber (TPC) with a sensitive volume of 19 X 20 X 6 cm3 f
ollowed by a parallel plate avalanche counter (sensitive volume 20 X 5
X 0.4 cm3) and a multiwire proportional chamber (MWPC) with 96 wires
2 mm apart. The gas used was an argon/methane/isobutane mixture (ratio
60/20/20) at atmospheric pressure. TMAE at 15-degrees-C served as the
photosensitive component. The measurements were done with a calibrate
d VUV photon source. The following results were obtained: spatial reso
lution of the MWPC 1.2 mm, spatial resolution of the TPC 800 mum, atta
chment length (13.0 +/- 1.6) cm and photon detection efficiency 4.2% c
orresponding to N0 = 25 cm - 1.