K. Martens et al., AGING EFFECTS OBSERVED IN THE CERN OMEGA RICH, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 343(1), 1994, pp. 258-262
We report on the new drift chambers of the Omega RICH used in the hype
ron beam experiment WA89 at the CERN-SPS and in the heavy-ion experime
nt WA94. After four data-taking runs in 1990/91/92 it was found that t
he anode wires of the chambers were coated with a smooth layer of 1 mu
m thickness. Pulse heights were found to be reduced considerably with
respect to those observed on new wires. Washing with alcohol and water
in an ultrasonic bath restored the original pulse heights. In 1993 th
e RICH is running again in experiment WA89.