MEASUREMENT DEVICE FOR THE IN-SITU MAREL NETWORK MONITORING STATION

Citation
J. Legrand et al., MEASUREMENT DEVICE FOR THE IN-SITU MAREL NETWORK MONITORING STATION, Onde electrique, 74(5), 1994, pp. 43-47
Citations number
NO
Categorie Soggetti
Telecommunications,"Engineering, Eletrical & Electronic
Journal title
ISSN journal
00302430
Volume
74
Issue
5
Year of publication
1994
Pages
43 - 47
Database
ISI
SICI code
0030-2430(1994)74:5<43:MDFTIM>2.0.ZU;2-V
Abstract
The aim of the MAREL network is to automate the collection of data rel ative to the coastal water quality in order to follow up the levels an d trends of pollutant concentrations, to trigger alarms in the case of passing pre-defined thresholds or to obtain long time series for scie ntific needs. This article describes the subassemblies which make up t he special characteristics of the MAREL network measurement device: th e system for taking samples, the measuring chamber and the anti-foulin g device.