OPTIMIZATION OF THE ANALYTICAL PROCEDURE FOR CR, CU, NI, AND PB DETERMINATION BY ICP-AES IN MUNICIPAL LANDFILL LEACHATES

Citation
Mp. Papini et al., OPTIMIZATION OF THE ANALYTICAL PROCEDURE FOR CR, CU, NI, AND PB DETERMINATION BY ICP-AES IN MUNICIPAL LANDFILL LEACHATES, Microchemical journal, 50(2), 1994, pp. 191-200
Citations number
16
Categorie Soggetti
Chemistry Analytical
Journal title
ISSN journal
0026265X
Volume
50
Issue
2
Year of publication
1994
Pages
191 - 200
Database
ISI
SICI code
0026-265X(1994)50:2<191:OOTAPF>2.0.ZU;2-Z
Abstract
An ICP-AES-based procedure to determine Cr, Cu, Ni, and Pb in landfill leachates was optimized. Comparison of the performance of two differe nt concentric nebulizers (Meinhard and Zr-cone Jobin-Yvon) was conside red both with and without pretreatment of the samples. Moreover, calib ration by standards of different composition was used and compared to the standard addition procedure. The matrix effect depended on the dif ferent experimental conditions. By using the Zr-cone Jobin-Yvon nebuli zation system and calibrating with standard solutions of saline conten ts similar to those of the leachate the matrix effect was satisfactori ly compensated. Deviations from the reference concentration values wer e, in this case, less than 5% for all the metals considered. (C) 1994 Academic Press, Inc.