EVALUATION AND REDUCTION OF HARMONIC DISTORTION CAUSED BY SOLID-STATEVOLTAGE CONTROLLERS OF INDUCTION-MOTORS

Citation
Ls. Czarnecki et Ot. Tan, EVALUATION AND REDUCTION OF HARMONIC DISTORTION CAUSED BY SOLID-STATEVOLTAGE CONTROLLERS OF INDUCTION-MOTORS, IEEE transactions on energy conversion, 9(3), 1994, pp. 528-534
Citations number
7
Categorie Soggetti
Engineering, Eletrical & Electronic","Energy & Fuels
ISSN journal
08858969
Volume
9
Issue
3
Year of publication
1994
Pages
528 - 534
Database
ISI
SICI code
0885-8969(1994)9:3<528:EAROHD>2.0.ZU;2-M
Abstract
The harmonic distortion caused by a solid state AC voltage controller of an induction motor drive is evaluated. A conventional shunt harmoni c filter (SHF) for harmonic reduction for a group of such drives is co mpared with a harmonic blocking compensator (HBC). It is shown that th e HBC is more efficient in harmonic reduction than the SHF, especially , with distorted supply voltage. Moreover, the designer has more contr ol over the HBC than the SHF performance. The HBC, however, has a high er power rating than the SHF.