Test results for actively cooled, graphite RG-Ti type brazed to molybd
enum tube divertor mock-ups are presented. Particular attention was pa
id to finding a reliable, non-destructive method of investigating braz
ed joints. The mock-ups were ultrasonically tested and the results cor
related with the microstructure of the joints. Two types of tests were
carried out: screening tests with a stepped increase of the surface h
eat flux from shot to shot and thermal cycling tests at a fixed power
density level. The heat loads were varied in the range from 6 MW/m(2)
to 12 MW/m(2). About 150 cycles of heat loads with a power density of
10 MW/m(2) were realized and no macrodamage was found. The heat flux e
xperiments were accompanied by detailed metallographic investigations.