A METHOD FOR TEMPERATURE-MEASUREMENTS IN CIRCULATING FLUIDIZED-BED COMBUSTORS

Citation
Mr. Golriz et B. Sunden, A METHOD FOR TEMPERATURE-MEASUREMENTS IN CIRCULATING FLUIDIZED-BED COMBUSTORS, Experimental thermal and fluid science, 9(3), 1994, pp. 274-282
Citations number
27
Categorie Soggetti
Engineering, Mechanical","Phsycs, Fluid & Plasmas",Thermodynamics
ISSN journal
08941777
Volume
9
Issue
3
Year of publication
1994
Pages
274 - 282
Database
ISI
SICI code
0894-1777(1994)9:3<274:AMFTIC>2.0.ZU;2-Y
Abstract
A method for measuring the local suspension temperature with a shielde d thermocouple in the combustion chamber of a circulating fluidized be d (CFB) boiler is described. The report also includes an estimation of the error in the local temperature measurement due to radiation losse s and some test results in the 12 MW(th) circulating fluidized bed boi ler at Chalmers University of Technology, Goteborg, Sweden. A typical suspension temperature distribution in the combustion chamber of the C FB boiler is provided, and the estimated uncertainty is found to be be low 4%, corresponding to 25-degrees-C at normal operating condition. T he experimental results are compared with available data in the litera ture.