TREATMENT OF POSTFILTRATION BLEB LEAK BY BLEB INJECTION OF AUTOLOGOUSBLOOD

Citation
Mf. Smith et al., TREATMENT OF POSTFILTRATION BLEB LEAK BY BLEB INJECTION OF AUTOLOGOUSBLOOD, Ophthalmic surgery, 25(9), 1994, pp. 636-637
Citations number
9
Categorie Soggetti
Ophthalmology,Surgery
Journal title
ISSN journal
0022023X
Volume
25
Issue
9
Year of publication
1994
Pages
636 - 637
Database
ISI
SICI code
0022-023X(1994)25:9<636:TOPBLB>2.0.ZU;2-6
Abstract
We treated a persistent, brisk bleb-leak after trabeculectomy with mit omycin C by bleb injection of autologous blood. Following preparation with povidone iodine, approximately 0.5 cc of whole autologous blood w as injected into the bleb at the slit lamp. The leak resolved after 36 hours, and after 9 months' follow up, continued to function well.