THE GLIDING-SHADOW METHOD AND ITS APPLICATION IN THE DESIGN OF A NEW FILM BADGE FOR THE MEASUREMENT OF THE PERSONAL DOSE-EQUIVALENT H-P(10)

Citation
P. Ambrosi et al., THE GLIDING-SHADOW METHOD AND ITS APPLICATION IN THE DESIGN OF A NEW FILM BADGE FOR THE MEASUREMENT OF THE PERSONAL DOSE-EQUIVALENT H-P(10), PTB-Mitteilungen, 104(5), 1994, pp. 334-338
Citations number
NO
Categorie Soggetti
Physics,Engineering
Journal title
ISSN journal
0030834X
Volume
104
Issue
5
Year of publication
1994
Pages
334 - 338
Database
ISI
SICI code
0030-834X(1994)104:5<334:TGMAIA>2.0.ZU;2-P
Abstract
A novel design principle for filters of a personal dosemeter badge, th e gliding-shadow method, is presented which allows the angular depende nce of the dosemeter response to be considerably reduced. This method has been applied to design a two-element film dosemeter. The new film dosemeter is capable of measuring H-p(10) for photons with energies ra nging from 17 keV to 1250 keV and angles of incidence up to 75 degrees with a maximum deviation of less than +/-40% using a linear combinati on as the dose calculating algorithm.