R. Garcia et al., DNA CONTENT IN NON-HODGKINS-LYMPHOMA - COMPARISON BETWEEN FLOW-CYTOMETRY AND CYTOGENETICS IN FRESH AND PARAFFIN-EMBEDDED TISSUE, Acta oncologica, 33(6), 1994, pp. 621-625
DNA content of 36-non-Hodgkin's lymphomas was analyzed by flow cytomet
ry (FCM) and cytogenetics (CG), 21 in fresh and 15 in paraffin-embedde
d tissue. The results of both techniques were coincident in 60% of the
fresh tissue samples and in 45% of the paraffin-embedded ones, the re
ason for this difference could be the poor resolution of DNA histogram
s from paraffin-embedded tissue. All samples judged as aneuploid by FC
M were aneuploid also by CG. Some samples,vith a hyperdiploid populati
on by CG gave a diploid population by FCM with a 'false' high DNA-synt
hesis (S) fraction. From a technical point of view, CG and FCM have to
be performed on the same fresh tissue.