P. Baldi et al., COMPARISON BETWEEN DIFFERENCE-FREQUENCY-GENERATION AND PARAMETRIC FLUORESCENCE IN QUASI-PHASE-MATCHED LITHIUM-NIOBATE STRIPE WAVE-GUIDES, IEEE journal of selected topics in quantum electronics, 2(2), 1996, pp. 385-395
Tuning curves and gain are two relevant parameters for integrated opti
cal parametric oscillators, We show in this paper that they can be det
ermined with a good precision without building a high-finesse cavity b
y measurement of the optical parametric fluorescence and difference-fr
equency generation. In the first part of this paper, we compare theore
tically the guided optical parametric fluorescence and the guided diff
erence-frequency generation in the quasi-phase matching configuration.
In the second part, we compare experimental results on optical parame
tric fluorescence in the 1.2-2.2-mu m region and optical difference-fr
equency generation from a 1,55-mu m laser diode using a pump wavelengt
h between 775-795 mm in quasi-phase-matched lithium niobate stripe wav
eguides. This comparison shows that the gain measured by both methods
is identical, but, while parametric fluorescence allows us to obtain t
he quasi-phase-matching curve, the difference-frequency generation giv
es a simpler and more accurate measurement of the gain, The combinatio
n of these two techniques provides therefore a powerful tool for evalu
ating the different fabrication processes of the nonlinear waveguides,
without actually fabricating a parametric oscillator.