MEASUREMENT OF DIRECT-CONTACT CONDENSATION OF PURE SATURATED VAPOR ONAN INJECTION SPRAY BY APPLYING PULSED LASER HOLOGRAPHY

Citation
F. Mayinger et A. Chavez, MEASUREMENT OF DIRECT-CONTACT CONDENSATION OF PURE SATURATED VAPOR ONAN INJECTION SPRAY BY APPLYING PULSED LASER HOLOGRAPHY, International journal of heat and mass transfer, 35(3), 1992, pp. 691-702
Citations number
21
ISSN journal
00179310
Volume
35
Issue
3
Year of publication
1992
Pages
691 - 702
Database
ISI
SICI code
0017-9310(1992)35:3<691:MODCOP>2.0.ZU;2-7
Abstract
An application of pulsed laser holography for direct measurement of th e growth of subcooled spray droplets in a pure saturated vapour is pre sented. The spray flow corresponds to intermediate and high droplet Re ynolds numbers (100 less-than-or-equal-to Re less-than-or-equal-to 350 0) while the vapour pressure is varied in a wide range of reduced pres sures (0.03 less-than-or-equal-to p(r) less-than-or-equal-to 0.3). The holographic reconstructions reveal a strong relation between the vapo ur pressure and the spray geometry. At moderate liquid flow rate and r elatively high vapour pressure, subsequent pressure increments produce dramatic changes in the spray geometry and considerably reduce the co ndensation rate.