INVESTIGATION OF GENERATOR LOAD INTERACTION IN THE ANGARA-5 INSTALLATION

Citation
Ev. Grabovskii et al., INVESTIGATION OF GENERATOR LOAD INTERACTION IN THE ANGARA-5 INSTALLATION, Instruments and experimental techniques, 35(5), 1992, pp. 840-844
Citations number
10
Categorie Soggetti
Instument & Instrumentation",Engineering
ISSN journal
00204412
Volume
35
Issue
5
Year of publication
1992
Part
2
Pages
840 - 844
Database
ISI
SICI code
0020-4412(1992)35:5<840:IOGLII>2.0.ZU;2-F
Abstract
The generator-load interaction in the Angara-5 installation is investi gated. The electromagnetic processes in uniform transmission lines are described in terms of the incident and reflected waves, which means t he current and voltage at any site of the line can be calculated; the energy reflectivity at nonregularities can be determined, and the rela tion between the readings of probes located at different sites can be established. The generator load and breakdown time of the separating d iaphragm (of the accelerator tube) are determined as functions of time . The results are interpreted. The energy reflectivity at the end of t he short-circuited transmission line is close to unity, and in the cas e of an energy absorbing load it is about 0.5.