PERFORMANCE RATING METHOD OF THERMOSIPHON SOLAR WATER-HEATERS

Authors
Citation
Bj. Huang, PERFORMANCE RATING METHOD OF THERMOSIPHON SOLAR WATER-HEATERS, Solar energy, 50(5), 1993, pp. 435-440
Citations number
4
Categorie Soggetti
Energy & Fuels
Journal title
ISSN journal
0038092X
Volume
50
Issue
5
Year of publication
1993
Pages
435 - 440
Database
ISI
SICI code
0038-092X(1993)50:5<435:PRMOTS>2.0.ZU;2-0
Abstract
A rating method for the thermal performance of thermosyphon solar wate r heaters was developed. Except that the outdoor test procedure still follows the Taiwan Standard CNS B7277, a system characteristic efficie ncy eta(s) which is defined as the alpha0 value. corrected at M/A(c) = 75 kg/m2, was derived so that eta(s) is independent of the M/A(c) r atio. Here, eta(s) can be evaluated by linear regression analysis of the test data. It is found from a series of tests for 31 systems that eta(s) is independent of M/A(c) indeed, and thus can be used to rate the thermal performance of different thermosyphon solar water heaters during the energy-collecting period. The cooling loss during the no-ra diation period is rated by the system cooling time constant tau(c). Th e present rating method associated with the Taiwan Standard CNS B7277 has been implemented for more than three years and is accepted by the Taiwan solar industry.