Ad. Cooper et Tm. Jefferies, SEMIPREPARATIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC RESOLUTION OFBROMPHENIRAMINE ENANTIOMERS USING BETA-CYCLODEXTRIN IN THE MOBILE PHASE, Journal of chromatography, 637(2), 1993, pp. 137-143
The semi-preparative reversed-phase HPLC separation of brompheniramine
enantiomers using beta-cyclodextrin as a chiral mobile phase additive
is described. Enantiomers were recovered free from mobile phase compo
nents on-line by a novel column switching procedure. On a 250 mm x 10
mm I.D. cyano column, a throughput of 8 mg per hour (0.65 mg per gram
column packing per hour) was achieved at product optical purities of 8
8% and above. This was achieved using two passes through the system. C
omparison is made with other reported semi-preparative chiral separati
ons using beta-cyclodextrin, and the potential utility of the describe
d method discussed.