A COMPARISON OF THE RATE OF SPACE CLOSURE USING A NICKEL-TITANIUM SPRING AND AN ELASTIC MODULE - A CLINICAL-STUDY

Citation
Rha. Samuels et al., A COMPARISON OF THE RATE OF SPACE CLOSURE USING A NICKEL-TITANIUM SPRING AND AN ELASTIC MODULE - A CLINICAL-STUDY, American journal of orthodontics and dentofacial orthopedics, 103(5), 1993, pp. 464-467
Citations number
8
Categorie Soggetti
Dentistry,Oral Surgery & Medicine
ISSN journal
08895406
Volume
103
Issue
5
Year of publication
1993
Pages
464 - 467
Database
ISI
SICI code
0889-5406(1993)103:5<464:ACOTRO>2.0.ZU;2-S
Abstract
A study of the efficiency of space closure after premolar extraction w as undertaken, comparing a nickel-titanium closed coil spring and an e lastic retraction module by using sliding mechanics along an 0.019 x 0 .025-inch stainless steel arch wire in 0.022 x 0.028-inch preadjusted stainless steel brackets. The rate of space closure in 17 subjects was analyzed from study models and was found to be significantly greater and more consistent with the nickel-titanium closed coil springs than with the elastic modules, in both arches. There were no clinically obs ervable differences in the tooth positions between the respective tech niques.