CALCULATION OF CORONA ONSET VOLTAGE FOR DUCT-TYPE PRECIPITATORS

Citation
M. Abdelsalam et D. Wiitanen, CALCULATION OF CORONA ONSET VOLTAGE FOR DUCT-TYPE PRECIPITATORS, IEEE transactions on industry applications, 29(2), 1993, pp. 274-280
Citations number
16
Categorie Soggetti
Engineering,"Engineering, Eletrical & Electronic
ISSN journal
00939994
Volume
29
Issue
2
Year of publication
1993
Pages
274 - 280
Database
ISI
SICI code
0093-9994(1993)29:2<274:COCOVF>2.0.ZU;2-G
Abstract
In this paper, a pure theoretical method for calculating the onset vol tage of corona in duct-type precipitators that is independent of the a rrangement of discharge wires relative to the collecting plates is des cribed. This method is based on a criterion for self-recurring single electron avalanches in a known field distribution in the ionization zo ne surrounding the discharge wire. The results computed by this method are in reasonable agreement with those measured experimentally.