Lz. Zeng et al., A UNIFIED MODEL FOR THE PREDICTION OF BUBBLE DETACHMENT DIAMETERS IN BOILING SYSTEMS .1. POOL BOILING, International journal of heat and mass transfer, 36(9), 1993, pp. 2261-2270
A new model is proposed for the prediction of vapor bubble departure d
iameters in saturated pool boiling. The model utilizes a force balance
which follows a similar form as that used by Klausner et al. (Int. J.
Heat Mass Transfer 36, 651-662 (1993)) for flow boiling. The vapor bu
bble growth rate is a necessary input to the model, and its reliable e
stimation is required to predict accurately departure diameters. The m
odel has been tested over the following range of conditions: pressure,
0.02-2.8 bar; Jakob number, 4-869; and gravity, 1-0.014 g. It is demo
nstrated that over the wide range of boiling data considered the depar
ture diameter predicted using the present model is significantly impro
ved over existing correlations.