PERFORMANCE-CHARACTERISTICS OF AN ELECTRON-BEAM PUMPED XEF(C-]A) LASER WITH POSITIVE BRANCH INJECTION-CONTROLLED UNSTABLE RESONATORS

Citation
S. Yamaguchi et al., PERFORMANCE-CHARACTERISTICS OF AN ELECTRON-BEAM PUMPED XEF(C-]A) LASER WITH POSITIVE BRANCH INJECTION-CONTROLLED UNSTABLE RESONATORS, JPN J A P 1, 32(5A), 1993, pp. 1975-1979
Citations number
15
Categorie Soggetti
Physics, Applied
Volume
32
Issue
5A
Year of publication
1993
Pages
1975 - 1979
Database
ISI
SICI code
Abstract
The performance of injection controlled on-axis (centrally obstructed) and off -axis (non centrally obstructed) unstable resonators with mag nifications between 2 and 3 for an electron beam pumped high power XeF (C-->A) excimer laser system has been evaluated both in the near and f ar field. The angular beam divergence with the tested resonators was t ypically 2-3 times that of a diffraction-limited beam. A beam divergen ce angle as low as 128 murad was obtained with a circular cross-sectio n on-axis unstable resonator geometry of magnification 3. A peak brigh tness of 3 x 10(14) W/(sr.cm2) with a beam divergence of 160 murad was measured for a square cross-section off-axis resonator of magnificati on 2. In comparison with an on-axis resonator of the same magnificatio n, the experimental results demonstrated that an off -axis unstable re sonator offers an effective configuration for improving the laser beam quality without decreasing the output energy of an injection controll ed XeF(C-->A) excimer laser.