Dc. Ferreira et al., EVALUATION OF AN IN-VITRO DISSOLUTION AND PERMEATION APPARATUS FOR ORAL SOLID PHARMACEUTICAL DOSAGE FORMS, Drug development and industrial pharmacy, 23(4), 1997, pp. 387-392
An apparatus based in the USP dissolution test, the F-C-SL apparatus (
Ferreira-Costa-Sousa Lobo), was developed that allowed the simultaneou
s evaluation of the in vitro release and permeation of oral solid phar
maceutical dosage forms. The release rate in both dissolution devices
(USP and F-C-SL apparatus) was evaluated with acetaminophen tablets. D
ifferent test conditions (stirring rate and solvent volume ratio) were
investigated and no significant differences in acetaminophen release
rate were found between these apparatuses. In the F-C-SL apparatus, th
e in vitro permeation kinetics of acetaminophen were evaluated using s
ynthetic membranes and followed a zero-order kinetic.