DETERMINATION OF EXPLOSIVES RESIDUES IN SOILS BY MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - A COMPARATIVE-STUDY

Citation
W. Kleibohmer et al., DETERMINATION OF EXPLOSIVES RESIDUES IN SOILS BY MICELLAR ELECTROKINETIC CAPILLARY CHROMATOGRAPHY AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - A COMPARATIVE-STUDY, Journal of chromatography, 638(2), 1993, pp. 349-356
Citations number
14
Categorie Soggetti
Chemistry Analytical
Journal title
Volume
638
Issue
2
Year of publication
1993
Pages
349 - 356
Database
ISI
SICI code
Abstract
Micellar electrokinetic capillary chromatography (MECC) is investigate d for application as a complementary technique to reversed-phase high- performance liquid chromatography (HPLC) in the analysis of explosives residues. Separation efficiency, specificity, sensitivity, reproducib ility, analysis time and calibration linearity are examined by compari ng the suitability of HPLC and MECC in parallel analyses. Authentic so il samples from a former trinitrotoluene plant are examined, and the r esults show MECC to be a useful new technique in explosive analysis, y ielding good sensitivity, high resolution and short analysis times.